I�C was designed to communicate over short distances between printed circuit boards and is really a simple, 8-bit serial data bus. In the meantime, it isn’t only PCB-mountable pressure sensors that utilize the I�C signal for data transfer, but additionally pressure sensors remote from customer electronics.
Remote sensors usually have the benefit of being less sensitive to contaminated or aggressive media and being able to measure directly at the procedure. In the case of sensors mounted on the circuit board, the sensor element is, in many cases, exposed right to the medium. With remote sensors, steel or ceramic generally serve because the wetted surface.
I�C circuit
The I�C bus, alongside both supply lines, requires only two further lines:
SCL (serial clock line)
SDA (serial data line)
Additional possibilities through I�C
The I�C bus is really a well-known standard in electronics, offering additional possibilities for communication with a pressure sensor than with an analogue signal:
In the info protocol, as well as the pressure value, a temperature value and diagnostic information (for instance an integrity test of the info transfer) can be transmitted via a status byte.
Several pressure sensors could be connected to a bus line as ?slaves? to the customer electronics that functions as a ?master?.
On the client side, in contrast to the application of pressure sensors with analogue signals, the analogue-to-digital conversion of the pressure value for further signal processing is unnecessary since the pressure value is already present in digital form. This plays a part in faster and easier signal processing.
The electronics for communication could be constructed with standard components readily available on the market.
Often, I�C signal pressure sensors may also be optimised to take less energy, making them perfect for battery-powered applications. In the WIKA portfolio, for example, this applies to the MPR-1 pressure sensor module.
Boundary conditions by using I�C
Since I�C is not a fieldbus, long wire lengths are not recommended. The utmost wire length depends, at length, on the operating environment and the corresponding disturbing influences. I�C communication is best used in projects where in fact the pressure sensor or the pressure sensor module is built-into the customer product and therefore protected against external influences. It will also be noted that with any digitally processed signal, the response time because of discrete-time sampling will be somewhat slower than for an analogue, continuous signal.
Note
Your contact person will be happy to assist you to with any further questions on digital interfaces.
Distributed เกจวัดแรงดันน้ำ4หุน
Distributed Intelligence on the integration of pressure sensors into hydraulic systems
Fill below form and we’ll send you the whitepaper ?Distributed Intelligence?.
Name
Company
E-mail
Send
We?re committed to your privacy. We?ll use your details to get hold of you about our services. E mail us at socialmedia@wika.com to revoke your permission to use your information.

Leave a Reply