I�C was designed to communicate over short distances between printed circuit boards and is a simple, 8-bit serial data bus. For the time being, it is not only PCB-mountable pressure sensors that use the I�C signal for data transfer, but additionally pressure sensors remote from customer electronics.
Remote sensors will often have the benefit of being less sensitive to contaminated or aggressive media and to be able to measure directly at the procedure. In the case of sensors mounted directly on the circuit board, the sensor element is, in many cases, exposed directly to the medium. With remote sensors, steel or ceramic generally serve as the wetted surface.
I�C circuit
The I�C bus, alongside the two supply lines, requires only two further lines:
SCL (serial clock line)
SDA (serial data line)
Additional possibilities through I�C
The I�C bus is a well-known standard in electronics, offering additional possibilities for communication with a pressure sensor than with an analogue signal:
In the info protocol, as well as the pressure value, a temperature value and diagnostic information (for example an integrity test of the info transfer) could be transmitted with a status byte.
เกจวัดแก๊สหุงต้ม can be connected to a bus line as ?slaves? to the client electronics that functions as a ?master?.
On the customer side, as opposed to the use of pressure sensors with analogue signals, the analogue-to-digital conversion of the pressure value for further signal processing is unnecessary since the pressure value has already been within digital form. This plays a part in faster and easier signal processing.
The electronics for communication can be constructed with standard components easily available on the market.
Often, I�C signal pressure sensors are also optimised to consume less energy, making them ideal for battery-powered applications. In the WIKA portfolio, for instance, this pertains to the MPR-1 pressure sensor module.
Boundary conditions with the use of I�C
Since I�C isn’t a fieldbus, long wire lengths aren’t recommended. The maximum wire length depends, in detail, on the operating environment and the corresponding disturbing influences. I�C communication is most beneficial used in projects where the pressure sensor or the pressure sensor module is integrated into the customer product and thus protected against external influences. It should also be noted that with any digitally processed signal, the response time because of discrete-time sampling will undoubtedly be somewhat slower than for an analogue, continuous signal.
Note
Your contact person will undoubtedly be happy to help you with any further questions on digital interfaces.
Distributed Intelligence